1136_0 Differential Gas Pressure Sensor ±2kPa
This differential air pressure sensor plugs into an Analog Input or VINT Hub port and measures pressure from -2 kPa to 2 kPa.
The 1136 Differential Pressure Sensor is a dual ported air pressure sensor that measures the pressure difference between the two ports.
It can measure both positive and negative pressure from –2 kPa to +2 kPa.
- Includes 60cm Sensor Cable
Warning
This sensor is designed to measure the pressure of clean, non-condensing air. Contact with moist air (i.e, human breath), dusty air, or other gases can damage the sensor.
Sensor Properties
|
Sensor Type |
Gas Pressure (Differential) |
|
Sensor Output Type |
Ratiometric |
|
Pressure Differential Min |
-2 kPa |
|
Pressure Differential Max |
2 kPa |
|
Case Pressure Max |
75 kPa |
|
Pressure Resolution |
5 Pa |
|
Measurement Error Max |
± 6.5 % |
|
Warm-up Time |
20 ms |
|
Response Time Max |
1 ms |
Electrical Properties
|
Supply Voltage Min |
4.8 V DC |
|
Supply Voltage Max |
5.3 V DC |
|
Current Consumption Max |
10 mA |
|
Output Impedance |
1 kΩ |
|
Output Voltage Min |
500 mV DC |
|
Output Voltage Max |
4.5 V DC |
Physical Properties
|
Operating Temperature Min |
10 °C |
|
Operating Temperature Max |
60 °C |
|
Recommended Tubing Size |
3⁄32″ |